Merchandise Description
Wavelength 1340nm fiber optic coupler splitter coupling ratio twenty / eighty
Product Description
Description
The Single Manner Broadband Fiber Coupler based mostly on Two Parallel Fiber fused bi-conical taper technology. It has one or multi window. The devices are developed and produced to meet up with Telcordia GR-1209-Main requirements and RoHS compliant.
Produced in China dual window bare fiber 1×2 singlemode multimode fiber optical FBT splitter coupler
Fused Biconic Tapered (FBT) splitters are available with 1×2, 1×3, 1×4, 1×5, 1×6, 1×8,1×12, 1×16, 1×18, 1×20 and 1×24 configurations with single mode or multimode fiber.
Essential Characteristics
Lower Insertion Reduction
Large Channel Isolation
Large Security and trustworthiness
Compact situation dimensions
Optional break up ratio 10/90, twenty/80…
Qualified Underneath Telcordia GR-1221 and GR-1209
Apps Functions
Telecommunication system Lower surplus decline
Line check program Lower PDL
Access network Substantial dependability
OCT system
Amplifier
CATV
FTTX
Passive Optical Networks (PON)
Electronic, hybrid online video methods
CATV hyperlinks & Fiber sensors
Ordering Info
SSBC-twelve-34-twenty-E-09-05-A2-00
| Ports | Wavelength | Coupling ratio | Fiber Kind | Pigtail Dia. | Pigtail Size | Package | Connector Sort |
| twelve=1×2 | eighty two=820nm | 01=01/ninety nine | H=Hello 780 | 02=.25mm | 05=50cm | A1(2, 3,) | FU(A)=FC/UPC(APC) |
| 22=2×2 | 98=980nm | 02=02/ninety eight | F=Flex 1060 | 09=.9mm | ten=100cm | B1(2) | SU(A)=SC/UPC(APC) |
| / | E=SMF-28e | 2=2mm | C1 | ||||
| thirteen=1310nm | 40=40/60 | B=SMF-28e XB | 3=3mm | 20=200cm | D1 | LU(A)=LC/UPC(APC) | |
| 35=1310&1550nm | 00=fifty/fifty | / | X=Customization | ||||
Package and Mounting Dimension (mm)
| Stainless Metal Tube (A) | Plastic Box (B) | Aluminum alloy Box (C) | Aluminum alloy Rack (D) | ||||||||||
| Outline | Outline | Outline | Mounting | Outline | Mounting | Outline | |||||||
| A1=Φ3×50 | A5=Φ5.5×34 | B1=90x20x9.5 | 50x12x2Φ3.2 | C1=85x18x8.4 | 44.5x13x2Φ3 | D1=129x29x160 1U LGX | |||||||
| A2=Φ3×54 | A6=Φ5.5×38 | B2=100x80x10 | 70×73.5×4Φ3.two | C2=90x72x8 | 86x68x4Φ3 | D2=129x58x160 2U LGX | |||||||
| A3=Φ3×60 | A7=Φ5.5×50 | B3=120x80x18 | 80×74.5×4Φ3.two | C3=110x95x7.five | 99x84x4Φ3.five | D3=485×43.5×230 1U 19′ RACK | |||||||
| A4=Φ5×70 | A8=Φ5.5×64 | B4=141x115x18 | 100x106x4Φ3.2 | C4=110x95x15 | 99x84x4Φ3.five | D4=485x87x230 2U 19′ RACK | |||||||
| Merchandise | φ0.25 Stainless | φ0.9 Stainless | φ2/3 Stainless | φ0.9(φ2,φ3) Plastic | φ0.9(φ2/φ3) Aluminum Alloy | LGX | 19′ Rack | ||||||
| 1×2 | A1 | A2 | A4 | B1 | C1 | D1 | D3 | ||||||
| 2×2 | A1 | A3 | A4 | B1 | C1 | D1 | D3 | ||||||
Specification
| Functioning Wavelength(nm) |
820±40/980±40/ 1310±40/1550±40 |
980&1550±40/ 1310&1490&1550±40 |
Parameter | Unit | Price | ||
| Coupling Ratio (%) |
Insertion Decline (dB) | Fiber Sort | / | Hi 780/ Flex 1060/ SMF-28e/ SMF-28e XB |
|||
| Tap | Signal | Faucet | Signal | ||||
| 01/99 | 19.-21. | ≤0.20 | eighteen.5-21.5 | ≤0.25 | PDL | dB | Typ.:<0.1 Max.:<0.15 |
| 03/ninety seven | fourteen.6-16.two | ≤0.thirty | 14.5-16.5 | ≤0.30 | Directivity | dB | >55 |
| 05/ninety five | twelve.4-13.eight | ≤0.35 | 12.-14.five | ≤0.forty five | Return Loss | dB | >50 |
| ten/90 | 9.70—ten.7 | ≤0.60 | nine.70-eleven.2 | ≤0.60 | Excessive Reduction | dB | Typ.:<0.1 Max.:<0.2 |
| twenty/eighty | 6.70—7.60 | ≤1.fifteen | six.60—7.eighty | ≤1.15 | Pigtail Dia. | mm | .twenty five /.9 / 2 / 3 |
| 33/67 | four.65—5.sixty five | ≤1.70 | four.fifty—5.eighty five | ≤1.eighty | Pigtail Length | cm | >100 |
| forty/60 | 3.95—4.30 | ≤2.fifty | three.70—4.70 | ≤2.70 | Functioning Tem. | ºC | -10~ +70 |
| 50/fifty | 2.eighty five—3.thirty | 2.eighty—3.40 | Storage Tem. | ºC | -forty~ +eighty five | ||
| To Be Negotiated | 1 Piece (Min. Order) |
###
| Type: | Optical Fiber Distribution Box |
|---|---|
| Wiring Devices: | ODF |
| Certification: | ISO, RoHS |
| Condition: | New |
| Ports: | 1X2 |
| Connector Type: | None |
###
| Customization: |
Available
|
|---|
###
| Ports | Wavelength | Coupling ratio | Fiber Type | Pigtail Dia. | Pigtail Length | Package | Connector Type |
| 12=1×2 | 82=820nm | 01=01/99 | H=Hi 780 | 02=0.25mm | 05=50cm | A1(2, 3,) | FU(A)=FC/UPC(APC) |
| 22=2×2 | 98=980nm | 02=02/98 | F=Flex 1060 | 09=0.9mm | 10=100cm | B1(2) | SU(A)=SC/UPC(APC) |
| / | E=SMF-28e | 2=2mm | C1 | ||||
| 13=1310nm | 40=40/60 | B=SMF-28e XB | 3=3mm | 20=200cm | D1 | LU(A)=LC/UPC(APC) | |
| 35=1310&1550nm | 00=50/50 | / | X=Customization | ||||
###
| Stainless Steel Tube (A) | Plastic Box (B) | Aluminum alloy Box (C) | Aluminum alloy Rack (D) | ||||||||||
| Outline | Outline | Outline | Mounting | Outline | Mounting | Outline | |||||||
| A1=Φ3×50 | A5=Φ5.5×34 | B1=90x20x9.5 | 50x12x2Φ3.2 | C1=85x18x8.4 | 44.5x13x2Φ3 | D1=129x29x160 1U LGX | |||||||
| A2=Φ3×54 | A6=Φ5.5×38 | B2=100x80x10 | 70×73.5×4Φ3.2 | C2=90x72x8 | 86x68x4Φ3 | D2=129x58x160 2U LGX | |||||||
| A3=Φ3×60 | A7=Φ5.5×50 | B3=120x80x18 | 80×74.5×4Φ3.2 | C3=110x95x7.5 | 99x84x4Φ3.5 | D3=485×43.5×230 1U 19′ RACK | |||||||
| A4=Φ5×70 | A8=Φ5.5×64 | B4=141x115x18 | 100x106x4Φ3.2 | C4=110x95x15 | 99x84x4Φ3.5 | D4=485x87x230 2U 19′ RACK | |||||||
| Item | φ0.25 Stainless | φ0.9 Stainless | φ2/3 Stainless | φ0.9(φ2,φ3) Plastic | φ0.9(φ2/φ3) Aluminum Alloy | LGX | 19′ Rack | ||||||
| 1×2 | A1 | A2 | A4 | B1 | C1 | D1 | D3 | ||||||
| 2×2 | A1 | A3 | A4 | B1 | C1 | D1 | D3 | ||||||
###
| Operating Wavelength(nm) |
820±40/980±40/ 1310±40/1550±40 |
980&1550±40/ 1310&1490&1550±40 |
Parameter | Unit | Value | ||
| Coupling Ratio (%) |
Insertion Loss (dB) | Fiber Type | / | Hi 780/ Flex 1060/ SMF-28e/ SMF-28e XB |
|||
| Tap | Signal | Tap | Signal | ||||
| 01/99 | 19.0-21.0 | ≤0.20 | 18.5-21.5 | ≤0.25 | PDL | dB | Typ.:<0.1 Max.:<0.15 |
| 03/97 | 14.6-16.2 | ≤0.30 | 14.5-16.5 | ≤0.30 | Directivity | dB | >55 |
| 05/95 | 12.4-13.8 | ≤0.35 | 12.0-14.5 | ≤0.45 | Return Loss | dB | >50 |
| 10/90 | 9.70—10.7 | ≤0.60 | 9.70-11.2 | ≤0.60 | Excess Loss | dB | Typ.:<0.1 Max.:<0.2 |
| 20/80 | 6.70—7.60 | ≤1.15 | 6.60—7.80 | ≤1.15 | Pigtail Dia. | mm | 0.25 /0.9 / 2 / 3 |
| 33/67 | 4.65—5.65 | ≤1.70 | 4.50—5.85 | ≤1.80 | Pigtail Length | cm | >100 |
| 40/60 | 3.95—4.30 | ≤2.50 | 3.70—4.70 | ≤2.70 | Operating Tem. | ºC | -10~ +70 |
| 50/50 | 2.85—3.30 | 2.80—3.40 | Storage Tem. | ºC | -40~ +85 | ||
| To Be Negotiated | 1 Piece (Min. Order) |
###
| Type: | Optical Fiber Distribution Box |
|---|---|
| Wiring Devices: | ODF |
| Certification: | ISO, RoHS |
| Condition: | New |
| Ports: | 1X2 |
| Connector Type: | None |
###
| Customization: |
Available
|
|---|
###
| Ports | Wavelength | Coupling ratio | Fiber Type | Pigtail Dia. | Pigtail Length | Package | Connector Type |
| 12=1×2 | 82=820nm | 01=01/99 | H=Hi 780 | 02=0.25mm | 05=50cm | A1(2, 3,) | FU(A)=FC/UPC(APC) |
| 22=2×2 | 98=980nm | 02=02/98 | F=Flex 1060 | 09=0.9mm | 10=100cm | B1(2) | SU(A)=SC/UPC(APC) |
| / | E=SMF-28e | 2=2mm | C1 | ||||
| 13=1310nm | 40=40/60 | B=SMF-28e XB | 3=3mm | 20=200cm | D1 | LU(A)=LC/UPC(APC) | |
| 35=1310&1550nm | 00=50/50 | / | X=Customization | ||||
###
| Stainless Steel Tube (A) | Plastic Box (B) | Aluminum alloy Box (C) | Aluminum alloy Rack (D) | ||||||||||
| Outline | Outline | Outline | Mounting | Outline | Mounting | Outline | |||||||
| A1=Φ3×50 | A5=Φ5.5×34 | B1=90x20x9.5 | 50x12x2Φ3.2 | C1=85x18x8.4 | 44.5x13x2Φ3 | D1=129x29x160 1U LGX | |||||||
| A2=Φ3×54 | A6=Φ5.5×38 | B2=100x80x10 | 70×73.5×4Φ3.2 | C2=90x72x8 | 86x68x4Φ3 | D2=129x58x160 2U LGX | |||||||
| A3=Φ3×60 | A7=Φ5.5×50 | B3=120x80x18 | 80×74.5×4Φ3.2 | C3=110x95x7.5 | 99x84x4Φ3.5 | D3=485×43.5×230 1U 19′ RACK | |||||||
| A4=Φ5×70 | A8=Φ5.5×64 | B4=141x115x18 | 100x106x4Φ3.2 | C4=110x95x15 | 99x84x4Φ3.5 | D4=485x87x230 2U 19′ RACK | |||||||
| Item | φ0.25 Stainless | φ0.9 Stainless | φ2/3 Stainless | φ0.9(φ2,φ3) Plastic | φ0.9(φ2/φ3) Aluminum Alloy | LGX | 19′ Rack | ||||||
| 1×2 | A1 | A2 | A4 | B1 | C1 | D1 | D3 | ||||||
| 2×2 | A1 | A3 | A4 | B1 | C1 | D1 | D3 | ||||||
###
| Operating Wavelength(nm) |
820±40/980±40/ 1310±40/1550±40 |
980&1550±40/ 1310&1490&1550±40 |
Parameter | Unit | Value | ||
| Coupling Ratio (%) |
Insertion Loss (dB) | Fiber Type | / | Hi 780/ Flex 1060/ SMF-28e/ SMF-28e XB |
|||
| Tap | Signal | Tap | Signal | ||||
| 01/99 | 19.0-21.0 | ≤0.20 | 18.5-21.5 | ≤0.25 | PDL | dB | Typ.:<0.1 Max.:<0.15 |
| 03/97 | 14.6-16.2 | ≤0.30 | 14.5-16.5 | ≤0.30 | Directivity | dB | >55 |
| 05/95 | 12.4-13.8 | ≤0.35 | 12.0-14.5 | ≤0.45 | Return Loss | dB | >50 |
| 10/90 | 9.70—10.7 | ≤0.60 | 9.70-11.2 | ≤0.60 | Excess Loss | dB | Typ.:<0.1 Max.:<0.2 |
| 20/80 | 6.70—7.60 | ≤1.15 | 6.60—7.80 | ≤1.15 | Pigtail Dia. | mm | 0.25 /0.9 / 2 / 3 |
| 33/67 | 4.65—5.65 | ≤1.70 | 4.50—5.85 | ≤1.80 | Pigtail Length | cm | >100 |
| 40/60 | 3.95—4.30 | ≤2.50 | 3.70—4.70 | ≤2.70 | Operating Tem. | ºC | -10~ +70 |
| 50/50 | 2.85—3.30 | 2.80—3.40 | Storage Tem. | ºC | -40~ +85 | ||
What Is a Coupling?
A coupling is a mechanical device that links two shafts together and transmits power. Its purpose is to join rotating equipment while permitting a small amount of misalignment or end movement. Couplings come in a variety of different types and are used in a variety of applications. They can be used in hydraulics, pneumatics, and many other industries.
Types
Coupling is a term used to describe a relationship between different modules. When a module depends on another, it can have different types of coupling. Common coupling occurs when modules share certain overall constraints. When this type of coupling occurs, any changes to the common constraint will also affect the other modules. Common coupling has its advantages and disadvantages. It is difficult to maintain and provides less control over the modules than other types of coupling.
There are many types of coupling, including meshing tooth couplings, pin and bush couplings, and spline couplings. It is important to choose the right coupling type for your specific application to get maximum uptime and long-term reliability. Listed below are the differences between these coupling types.
Rigid couplings have no flexibility, and require good alignment of the shafts and support bearings. They are often used in applications where high torque is required, such as in push-pull machines. These couplings are also useful in applications where the shafts are firmly attached to one another.
Another type of coupling is the split muff coupling. This type is made of cast iron and has two threaded holes. The coupling halves are attached with bolts or studs.
Applications
The coupling function is an incredibly versatile mathematical tool that can be used in many different scientific domains. These applications range from physics and mathematics to biology, chemistry, cardio-respiratory physiology, climate science, and electrical engineering. The coupling function can also help to predict the transition from one state to another, as well as describing the functional contributions of subsystems in the system. In some cases, it can even be used to reveal the mechanisms that underlie the functionality of interactions.
The coupling selection process begins with considering the intended use of the coupling. The application parameters must be determined, as well as the operating conditions. For example, if the coupling is required to be used for power transmission, the design engineer should consider how easily the coupling can be installed and serviced. This step is vital because improper installation can result in a more severe misalignment than is specified. Additionally, the coupling must be inspected regularly to ensure that the design parameters remain consistent and that no detrimental factors develop.
Choosing the right coupling for your application is an important process, but it need not be difficult. To find the right coupling, you must consider the type of machine and environment, as well as the torque, rpm, and inertia of the system. By answering these questions, you will be able to select the best coupling for your specific application.
Problems
A coupling is a device that connects two rotating shafts to transfer torque and rotary motion. To achieve optimal performance, a coupling must be designed for the application requirements it serves. These requirements include service, environmental, and use parameters. Otherwise, it can prematurely fail, causing inconvenience and financial loss.
In order to prevent premature failure, couplings should be properly installed and maintained. A good practice is to refer to the specifications provided by the manufacturer. Moreover, it is important to perform periodic tests to evaluate the effectiveness of the coupling. The testing of couplings should be performed by qualified personnel.

editor by czh 2022-12-31